1.
Vestn Oftalmol ; 138(5): 66-72, 2022.
Artigo em Russo | MEDLINE | ID: mdl-36288419

RESUMO

PURPOSE: To investigate the condition of the ocular surface and the effectiveness of Taflotan for long-term therapy in patients with newly diagnosed primary open-angle glaucoma in real clinical practice. MATERIAL AND METHODS: This publication presents data form a retrospective observational study that analyzed newly diagnosed glaucoma patients that have been using 1 drop/day of Taflotan in the evening for 12 months. All patients were examined at baseline, and after 1 month and 12 months of treatment, recording intraocular pressure (IOP), retinal photosensitivity indicators (MD, PSD), thickness of the retinal nerve fiber layer (RNFL), and assessing the condition of the ocular surface by Schirmer test, tear breakup time (TBUT), ocular surface disease index (OSDI) questionnaire, as well as measurement of the lacrimal meniscus height and corneal staining with lissamine green. RESULTS: IOP effectively decreased in all patients using Taflotan, reaching the target pressure by 1 month after therapy initiation. IOP decreased from 25±4 mm Hg at baseline to 17±3mm Hg after 1 month with further decrease down to 16±3 mm Hg after 12 months of therapy. Retinal photosensitivity (MD and PSD) and RNFL thickness did not differ from baseline, and correlated to glaucoma stage. The indicators of the condition of the ocular surface had no significant differences between the baseline, 1-month and 12-month time points. CONCLUSION: Taflotan effectively decreases IOP in newly diagnosed glaucoma patients, maintains stable automated perimetry indices and RNFL thickness, and does not affect the ocular surface throughout 12 months of therapy.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Hipertensão Ocular , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma/diagnóstico , Tonometria Ocular , Pressão Intraocular , Conservantes Farmacêuticos/uso terapêutico , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/tratamento farmacológico
2.
Vestn Oftalmol ; 137(1): 60-67, 2021.
Artigo em Russo | MEDLINE | ID: mdl-33610151

RESUMO

PURPOSE: To assess the influence of the frequency of retinal protective therapy courses on the indicators of regional hemodynamics of the eye. MATERIAL AND METHODS: The study included 17 patients (34 eyes) with a diagnosis of primary open-angle glaucoma (POAG), advanced stage. The patients were divided into 2 groups: the first group received a course of retinal protective therapy with Retinalamin every 3 months, the second group received a course of retinal protective therapy with Retinalamin every 6 months. All patients underwent standard ophthalmological examination including standard automatic perimetry according to the 24-2 program, optical coherence tomography angiography (OCT-A) of the macular area and optic disc. RESULTS: The comparison of hemodynamic parameters of all vascular plexuses of the retina at the beginning and at the end of the study, as well as intergroup comparison did not reveal any statistically significant differences (p>0.05). However, when studying the density and fractal dimension of the vascular bed, multidirectional trends were observed. Specifically, in the peripapillary region, there was a decrease in the length from 19.8 (1/mm) to 19.0 (1/mm) (p=0.37) and the density from 36.6% to 35.7% (p=0.63) of the vascular bed of the peripapillary capillary plexus of the retina in patients of the first group. In the superficial vascular plexus, the trend in the density of the vascular bed in both groups slightly changed (in group 1 - 38.1% and 38.3%, p=0.97; group 2 - 37.8% and 38.7%, p=0.46). The fractal dimension of the vascular bed in the first group tended to increase during treatment from 18.8 (1/mm) to 19.1 (1/mm) (p=0.5), while in the second group, on the contrary, it had tendency to decrease from 18.6 (1/mm) to 17.9 (1/mm) (p=0.63). In the deep vascular plexus, the density of the vascular bed trended to decrease in both groups, but in group 2 (42.5% and 42.4%, p=1.0) it was more pronounced than in the first group (42.5% and 42.6%, p=0.82). However, the fractal dimension of the vascular bed increased in group 1 (21.0 (1/mm) and 21.3 (1/mm), p=0.43) and showed a slight tendency to decrease in group 2 (21.5 (1/mm) and 21.0 (1/mm), p=0.86). CONCLUSION: The general trend of changes in hemodynamic parameters demonstrates a potential positive effect, especially in the data related to the deep vascular plexus.


Assuntos
Glaucoma de Ângulo Aberto , Disco Óptico , Angiografia , Angiofluoresceinografia , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Disco Óptico/diagnóstico por imagem , Projetos Piloto , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica